08 December 2014

打开

project->options->linker->config->override default

选择文件

C:\Program Files (x86)\IAR Systems\Embedded Workbench 6.0 Evaluation\8051\config\devices\Texas Instruments\lnk51ew_cc2530F256_banked.xcl

打开

project->options->General Options->Target

选择文件

C:\Program Files (x86)\IAR Systems\Embedded Workbench 5.4\8051\config\devices\Texas Instruments\CC2530F256.i51

Problem

在IAR 8.1中,基于CC2530F256芯片对Z-STACK进行builder,如果对IAR环境设置不当会出现:

Fatal Error[e72]: Segment ZIGNV_ADDRESS_SPACE must be defined in a segment definition option (-Z, -b or -P)

解决方法如下:

1、在General options设置:

选Target, 在Device information下的Device选

C:\Program Files\IAR Systems\Embedded Workbench 6.0 for 8051 Evaluation\8051\config\devices\Texas Instruments 下的:CC2530F256.i51

2、Linker设置

1)选config页面,在link configuration file下选择上override default选项,点击选择上f8w2530.xcl文件(缺省),即: C:\cc2530_example\link_long_slice_cc2530\20131205\cord\ZStack-CC2530- 2.3.0-1.4.0\Projects\zstack\Tools\CC2530DB\f8w2530.xcl

2)在output页面 在output file选择上选项override default,并填写修改为:coord.hex文件

3、Debug设置

Setup页面,Driver下选择Texas Instruments



blog comments powered by Disqus